Fujitsu R410A Manual

The Fujitsu R410A is a high-performance air conditioning system designed for residential and commercial use, featuring advanced inverter technology, energy-efficient operation, multiple operating modes (cooling, heating, dehumidification, fan), intelligent temperature control, remote control operation, timer functions, air swing control, and comprehensive safety features. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Components 7. Operating Modes 8. Maintenance Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Indoor unit, Outdoor unit, Remote Control, Power cable, Drain hose, Mounting bracket.

FeatureDescription
Inverter TechnologyEnergy-efficient operation with precise temperature control
Operating ModesCooling, Heating, Dehumidification, Fan only
Temperature Range16°C - 30°C (Cooling), 16°C - 30°C (Heating)
Air Swing ControlVertical and horizontal air direction adjustment
Timer Functions24-hour on/off timer
Sleep ModeAutomatic temperature adjustment for comfortable sleep
Turbo ModeRapid cooling/heating
Filter IndicatorReminder for filter cleaning
Auto RestartResumes previous settings after power interruption
Quiet OperationLow noise levels for peaceful environment

Installation

Unpack and inspect contents. Ensure proper location selection.

  1. Mount indoor unit: Install mounting bracket securely on wall.
  2. Install outdoor unit: Place on stable surface with proper clearance.
  3. Connect refrigerant pipes: Ensure proper connection between indoor and outdoor units.
  4. Electrical connections: Connect power cables following local electrical codes.
  5. Drain hose installation: Route drain hose for proper water drainage.

WARNING! Installation must be performed by qualified technician. Ensure proper ventilation and clearance around units.

First-Time Setup

Power on system; follow initial setup procedure.

  1. Remote control setup: Install batteries and point at indoor unit.
  2. Initial operation: Select desired mode (Cooling/Heating).
  3. Temperature setting: Set comfortable temperature using remote.
  4. Fan speed adjustment: Select appropriate fan speed for your needs.
  5. Timer programming: Set on/off timers as required.

CAUTION! Allow system to stabilize after first startup. Do not operate below minimum temperature.

Specifications

Controls and Settings

Access controls via remote control or indoor unit buttons.

Remote Control: POWER, MODE, TEMP ▲/▼, FAN SPEED, TIMER, SWING, TURBO, SLEEP, FILTER RESET.

Mode Selection: COOL, HEAT, DRY, FAN. Temperature Setting: 16°C - 30°C. Fan Speed: AUTO, HIGH, MEDIUM, LOW, QUIET. Timer: 24-hour programming. Swing: Vertical and horizontal air direction. Special Modes: TURBO for rapid cooling/heating, SLEEP for nighttime operation.

Connecting Components

Proper connection between indoor and outdoor units is essential.

  1. Refrigerant piping: Connect using flare nuts with proper torque.
  2. Electrical wiring: Connect power and communication cables.
  3. Drain hose: Ensure proper slope for water drainage.
  4. Communication cable: Connect between indoor and outdoor units.

Tip: All connections must be airtight and watertight. Use proper tools and techniques.

Operating Modes

Multiple operating modes for different needs.

  1. Cooling Mode: For hot weather conditions.
  2. Heating Mode: For cold weather conditions.
  3. Dry Mode: For dehumidification without significant cooling.
  4. Fan Mode: For air circulation only.
  5. Auto Mode: System automatically selects cooling or heating.
  6. Turbo Mode: Maximum cooling/heating capacity.
  7. Sleep Mode: Automatic temperature adjustment for sleeping comfort.

WARNING! Do not operate heating mode below specified outdoor temperature. Allow 3-minute interval between mode changes.

Maintenance Features

Auto Clean: Dries heat exchanger to prevent mold. Filter Indicator: Reminds when to clean air filter. Self-Diagnosis: Detects and displays error codes.

Care & Cleaning

Turn off power before cleaning. Clean air filter every 2 weeks. Use soft cloth for unit surface.

CAUTION! Do not use water above 40°C. Do not use abrasive cleaners. Keep unit dry during cleaning.

Regulatory Information

CE certified: Complies with European safety standards. RoHS compliant: Free of hazardous substances. Energy efficiency class: A++ for cooling, A+ for heating. For technical support, visit www.fujitsu-general.com or contact local authorized service center.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower supply/remoteCheck power connection; replace remote batteries; ensure proper remote operation.
Poor cooling/heatingDirty filters/settingsClean air filters; check temperature setting; ensure proper mode selection.
Water leakageClogged drainCheck drain hose for blockage; ensure proper installation.
Unusual noiseLoose parts/fanCheck for loose components; ensure fan blades are clean and balanced.
Error codes displayedSystem faultRefer to error code chart in manual; contact service if persistent.

Reset: Turn off power for 10 minutes then restart.

Service: Contact authorized Fujitsu service center; www.fujitsu-general.com

Fujitsu R410A Manual © - All Rights Reserved 2025