Fujitsu Mini Split Owners Manual

The Fujitsu Mini Split system is a high-efficiency ductless heating and cooling solution featuring inverter technology, multiple operating modes, remote control operation, programmable timers, air swing control, sleep mode, and advanced filtration system. Designed for residential and light commercial use with energy-saving features and quiet operation. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation Requirements 3. First-Time Setup 4. Technical Specifications 5. Controls and Operation 6. Remote Control Functions 7. Maintenance Procedures 8. Energy Saving Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Indoor unit, Outdoor unit, Remote control, Mounting bracket, Drain hose, Power cable, Communication wiring.

FeatureDescription
Inverter TechnologyVariable speed compressor for energy efficiency
Operating ModesCool, Heat, Fan, Dry, Auto
Temperature RangeCooling: 64°F-90°F; Heating: 60°F-86°F
Air Swing ControlAdjustable louvers for directional airflow
Sleep ModeAutomatic temperature adjustment for comfort
Timer FunctionsProgrammable on/off timers
Filter IndicatorReminder to clean air filter
Quiet OperationLow noise levels for indoor comfort
Auto RestartResumes previous settings after power outage
Wi-Fi ReadyOptional smart control capability

Installation Requirements

Professional installation recommended. Ensure proper location and clearances.

  1. Indoor unit placement: Minimum 7 feet from floor, away from direct sunlight and heat sources.
  2. Outdoor unit placement: Well-ventilated area, minimum 12 inches clearance on all sides.
  3. Electrical requirements: Dedicated circuit, proper voltage (208/230V), correct breaker size.
  4. Drainage: Proper slope for condensate drain line.
  5. Refrigerant lines: Properly insulated and sealed connections.

WARNING! Installation must be performed by qualified HVAC technician. Incorrect installation may void warranty.

First-Time Setup

After professional installation, perform initial setup and testing.

  1. Power on system: Turn on circuit breaker, wait for system initialization.
  2. Remote control setup: Install batteries, point at indoor unit signal receiver.
  3. Test operation: Select cooling mode, set temperature to 75°F, verify operation.
  4. Check airflow: Ensure proper air direction and volume.
  5. Verify drainage: Check for proper condensate flow.

CAUTION! Do not operate system if unusual noises or odors are detected.

Technical Specifications

Controls and Operation

Operate system using remote control or indoor unit buttons (if equipped).

Basic Operation: POWER button turns system on/off. MODE button cycles through operating modes (Cool, Heat, Fan, Dry, Auto). TEMP buttons adjust set temperature. FAN button controls fan speed (Auto, Low, Medium, High).

Advanced Features: SWING button adjusts vertical/horizontal louvers. TIMER button programs automatic on/off times. SLEEP mode optimizes temperature for nighttime comfort. QUIET mode reduces operating noise. I-FEEL function uses remote control as temperature sensor.

Remote Control Functions

Wireless remote control with LCD display and full function control.

  1. Power: Turns system on and off
  2. Mode: Selects operating mode (Cool/Heat/Fan/Dry/Auto)
  3. Temperature: Adjusts set temperature in 1° increments
  4. Fan Speed: Controls airflow (Auto/Low/Med/High)
  5. Swing: Adjusts air direction louvers
  6. Timer: Sets automatic start/stop times
  7. Sleep: Activates sleep mode operation
  8. Reset: Returns to default settings
  9. Filter: Resets filter cleaning reminder

Tip: Replace remote batteries every 6-12 months for optimal performance.

Maintenance Procedures

Regular maintenance ensures optimal performance and efficiency.

  1. Air filter cleaning: Clean every 2-4 weeks during operation
  2. Outdoor unit: Keep clear of debris, leaves, and snow
  3. Indoor unit: Wipe exterior with soft, dry cloth
  4. Drain line: Check for proper drainage monthly
  5. Professional service: Annual maintenance by qualified technician
  6. Winter operation: Keep outdoor unit clear of snow and ice
  7. Off-season: Run fan-only mode periodically to circulate air

WARNING! Do not attempt to repair refrigerant system. Contact qualified service technician.

Energy Saving Features

Inverter technology and smart features reduce energy consumption.

Eco Mode: Reduces energy usage while maintaining comfort. Auto Mode: Automatically selects optimal operating mode. Programmable Timers: Schedule operation to match occupancy. Temperature Limits: Prevent excessive heating/cooling. Fan Auto Mode: Adjusts fan speed based on temperature difference.

Care & Cleaning

Turn off power before cleaning. Use soft, dry cloth for exterior surfaces.

Air Filter Cleaning: Remove filter, rinse with lukewarm water, air dry completely before reinstalling. Outdoor Unit: Keep area clear, remove debris with soft brush. Indoor Unit: Wipe with dry cloth, do not use chemicals or abrasives.

CAUTION! Do not use water to clean electrical components. Do not operate without air filter installed.

Regulatory Information

UL listed and complies with applicable safety standards. EPA refrigerant handling certification required for service. Energy Star certified models available. Manufactured to ISO 9001 quality standards. Copyright © Fujitsu General America, Inc. For support, visit www.fujitsugeneral.com or contact 1-800-853-8573.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower supply/remoteCheck circuit breaker; replace remote batteries; ensure proper signal reception.
Poor cooling/heatingFilters/temperature settingClean air filters; check temperature setting; ensure adequate clearance around units.
Water leakageDrain line blockageCheck drain line for obstructions; ensure proper slope; contact technician if persistent.
Unusual noisesLoose parts/debrisCheck for loose panels; clear debris from outdoor unit; contact service technician.
Error codes displayedSystem faultNote error code; turn power off/on; if persistent, contact qualified technician.

Reset: Turn power off at breaker for 5 minutes, then restart.

Service: 1-800-853-8573; www.fujitsugeneral.com

Fujitsu Mini Split Owners Manual © - All Rights Reserved 2025