The Fujitsu Inverter AR-RY3 is a high-efficiency air conditioning system featuring inverter technology for energy savings, multiple operation modes (cooling, heating, dehumidification, fan), adjustable temperature range, timer functions, remote control operation, air flow direction control, sleep mode, and eco-friendly refrigerant. Designed for residential and commercial use with advanced climate control capabilities. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Inverter compressor, remote control, indoor unit, outdoor unit, temperature sensors, air filters, drainage system.
| Feature | Description |
|---|---|
| Inverter Technology | Energy-efficient variable speed compressor operation |
| Operation Modes | Cooling, Heating, Dehumidification, Fan Only, Auto |
| Temperature Range | 16°C - 30°C (60°F - 86°F) |
| Timer Functions | 24-hour on/off timer programming |
| Air Flow Control | Multi-directional louvers with adjustable speed |
| Sleep Mode | Automatic temperature adjustment for comfortable sleep |
| Remote Control | Infrared remote with LCD display |
| Auto Restart | Resumes previous settings after power interruption |
| Filter Indicator | Alerts when air filter needs cleaning |
| Quiet Operation | Low noise levels for peaceful environment |
Unpack and inspect all components. Ensure proper location selection.
WARNING! Installation must be performed by qualified technician only. Incorrect installation may cause injury or equipment damage.
Power on unit; configure initial settings via remote control.
CAUTION! Allow unit to stabilize for 5 minutes after power on before changing settings.
Access functions via remote control or indoor unit buttons.
Remote Control: POWER, MODE, TEMPERATURE ▲/▼, FAN SPEED, TIMER, SWING, SLEEP, TURBO, RESET, CLOCK.
Operation Modes: COOL (blue snowflake), HEAT (red sun), DRY (water drop), FAN (fan icon), AUTO (automatic selection). Fan Speed: Auto, Low, Medium, High, Quiet. Timer: 24-hour programming for ON/OFF operations. Special Functions: Sleep mode (gradual temperature adjustment), Turbo (rapid cooling/heating), Swing (air direction control), Filter reset.
Professional installation required for electrical and refrigerant connections.
Tip: Ensure all connections are tight and properly insulated before power on.
Multiple operation modes for different climate control needs.
WARNING! Do not operate heating mode below specified outdoor temperature to prevent compressor damage.
Auto Clean: Dries indoor unit to prevent mold growth. Filter Indicator: Alerts when air filter needs cleaning. Self-Diagnosis: Displays error codes for troubleshooting.
Turn off power before cleaning. Clean air filter every 2 weeks during peak usage.
CAUTION! Do not use water or chemicals on electrical components. Professional service required for internal cleaning.
CE Certified: Complies with European safety standards. Energy Efficiency Class: A++ for cooling, A+ for heating. RoHS Compliant: Free from hazardous substances. For technical support, visit www.fujitsu-general.com or contact authorized service centers. Refrigerant handling requires certified technicians.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power supply/remote | Check power connection; replace remote batteries; ensure proper aiming. |
| Poor cooling/heating | Filters/temperature setting | Clean air filters; check temperature setting; ensure doors/windows closed. |
| Water leakage | Drain blockage | Check drain hose for obstructions; ensure proper installation slope. |
| Unusual noise | Loose parts/fan | Check for loose panels; ensure fan blades are clean and unobstructed. |
| Error code displayed | System fault | Note error code; turn off power for 10 minutes; restart. If persists, contact service. |
Reset: Turn off at main power for 10 minutes, then restart.