Fujitsu Halcyon Mini Split Installation Manual
The Fujitsu Halcyon Mini Split system is a high-efficiency ductless air conditioning and heating solution featuring inverter technology, multiple operating modes, remote control operation, and advanced climate control capabilities. This manual covers proper installation procedures, safety guidelines, electrical requirements, refrigerant handling, and system commissioning for residential and light commercial applications.
Safety Precautions
Critical safety information for installers and technicians.
| Hazard | Precaution |
| Electrical shock | Disconnect power before servicing; use proper PPE |
| Refrigerant exposure | Wear safety glasses and gloves during handling |
| Heavy lifting | Use proper lifting techniques; two-person lift recommended |
| Sharp edges | Wear cut-resistant gloves during unit handling |
| High pressure | Release pressure before opening refrigerant circuits |
WARNING! Only qualified HVAC technicians should perform installation. Follow all local codes and regulations.
System Components
Complete system package includes indoor unit, outdoor unit, remote control, and installation accessories.
- Indoor Unit: Wall-mounted evaporator with LCD display
- Outdoor Unit: Condenser with inverter compressor
- Remote Control: Wireless controller with timer functions
- Installation Kit: Mounting bracket, communication cable, drain hose
- Refrigerant Lines: Pre-charged quick connect lines (specific models)
Pre-Installation Planning
Proper planning ensures optimal performance and efficiency.
- Select indoor unit location: Away from direct sunlight, heat sources, and moisture
- Determine outdoor unit placement: Stable surface with adequate clearance
- Plan refrigerant line routing: Minimum bends, proper insulation
- Verify electrical requirements: Dedicated circuit, proper voltage
- Check drainage requirements: Proper slope for condensate removal
Tip: Maintain minimum clearances: 6" top, 12" sides for indoor unit; 24" all around for outdoor unit.
Installation Requirements
Tools and materials needed for professional installation.
| Category | Requirements |
| Tools | Vacuum pump, manifold gauge, flaring tool, torque wrench, multimeter |
| Materials | Refrigerant, insulation, wall sleeve, electrical conduit |
| Electrical | 208/230V dedicated circuit, disconnect switch, proper wire gauge |
| Structural | Reinforced wall mounting, level surface for outdoor unit |
Mounting Procedures
Step-by-step mounting instructions for indoor and outdoor units.
- Install wall bracket: Level and secure to studs with provided hardware
- Create wall penetration: 3" hole with proper sleeve installation
- Mount indoor unit: Hang on bracket, ensure level position
- Place outdoor unit: Concrete pad or vibration-absorbing pads
- Secure outdoor unit: Anchor bolts or vibration isolation mounts
CAUTION! Ensure wall can support unit weight (typically 15-30 lbs for indoor unit).
Refrigerant Piping
Proper refrigerant line installation and connection procedures.
- Route refrigerant lines: Through wall sleeve with proper insulation
- Flare connections: 45-degree angle, burr-free finish
- Connect lines: Indoor unit first, then outdoor unit
- Torque fittings: Manufacturer specifications (typically 18-22 ft-lbs)
- Insulate lines: Complete vapor barrier on suction line
WARNING! Never use compression fittings. Always purge with nitrogen during brazing.
Electrical Connections
Wiring and electrical connection guidelines.
- Install disconnect: Within sight of outdoor unit
- Connect power wiring: Follow color coding and torque specifications
- Run communication cable: Shielded cable between indoor and outdoor units
- Ground all units: Proper grounding per NEC requirements
- Verify voltage: 208/230V ±10%
CAUTION! Turn off power at disconnect before making electrical connections.
Vacuum and Leak Testing
System evacuation and leak detection procedures.
- Pressure test: Dry nitrogen to 300-500 PSI, hold for minimum 30 minutes
- Evacuate system: Deep vacuum to 500 microns or less
- Hold vacuum: System should hold 1000 microns or less for 15 minutes
- Release refrigerant: Open service valves per manufacturer instructions
- Leak check: Electronic leak detector or bubble solution
System Commissioning
Final setup and performance verification.
- Power up system: Turn on disconnect switch
- Test operation: Cooling and heating modes
- Check temperatures: Supply/return air, discharge line
- Verify drainage: Proper condensate flow
- Program remote: Set clock, timer functions
- Customer orientation: Explain basic operation and maintenance
Troubleshooting
Common installation issues and solutions.
| Symptom | Possible Cause | Corrective Action |
| Unit not starting | Power supply, wiring | Check disconnect, verify voltage, inspect connections |
| Poor cooling | Refrigerant charge, airflow | Check superheat/subcooling, clean filters, verify fan operation |
| Water leakage | Drain line, installation angle | Clear drain line, ensure proper unit leveling |
| Error codes | Sensor failure, communication | Refer to service manual, check sensor readings |
| Noisy operation | Vibration, loose parts | Secure mounting, check for rattles, verify compressor mounts |
Specifications
- Cooling Capacity: 9,000 - 36,000 BTU/h (model dependent)
- Heating Capacity: 10,000 - 34,000 BTU/h (model dependent)
- Power Supply: 208/230V, 1-phase, 60Hz
- Refrigerant: R410A
- Operating Range: Cooling: 14°F to 115°F; Heating: -13°F to 75°F
- Sound Level: Indoor: 19-34 dB; Outdoor: 49-58 dB
- SEER Rating: Up to 33.1 (model dependent)
- Warranty: 5-7 years compressor, 1 year parts