Fujitsu Halcyon Mini Split Installation Manual

The Fujitsu Halcyon Mini Split system is a high-efficiency ductless air conditioning and heating solution featuring inverter technology, multiple operating modes, remote control operation, and advanced climate control capabilities. This manual covers proper installation procedures, safety guidelines, electrical requirements, refrigerant handling, and system commissioning for residential and light commercial applications.

1. Safety Precautions 2. System Components 3. Pre-Installation Planning 4. Installation Requirements 5. Mounting Procedures 6. Refrigerant Piping 7. Electrical Connections 8. Vacuum and Leak Testing 9. System Commissioning 10. Troubleshooting 11. Specifications

Safety Precautions

Critical safety information for installers and technicians.

HazardPrecaution
Electrical shockDisconnect power before servicing; use proper PPE
Refrigerant exposureWear safety glasses and gloves during handling
Heavy liftingUse proper lifting techniques; two-person lift recommended
Sharp edgesWear cut-resistant gloves during unit handling
High pressureRelease pressure before opening refrigerant circuits

WARNING! Only qualified HVAC technicians should perform installation. Follow all local codes and regulations.

System Components

Complete system package includes indoor unit, outdoor unit, remote control, and installation accessories.

Pre-Installation Planning

Proper planning ensures optimal performance and efficiency.

  1. Select indoor unit location: Away from direct sunlight, heat sources, and moisture
  2. Determine outdoor unit placement: Stable surface with adequate clearance
  3. Plan refrigerant line routing: Minimum bends, proper insulation
  4. Verify electrical requirements: Dedicated circuit, proper voltage
  5. Check drainage requirements: Proper slope for condensate removal

Tip: Maintain minimum clearances: 6" top, 12" sides for indoor unit; 24" all around for outdoor unit.

Installation Requirements

Tools and materials needed for professional installation.

CategoryRequirements
ToolsVacuum pump, manifold gauge, flaring tool, torque wrench, multimeter
MaterialsRefrigerant, insulation, wall sleeve, electrical conduit
Electrical208/230V dedicated circuit, disconnect switch, proper wire gauge
StructuralReinforced wall mounting, level surface for outdoor unit

Mounting Procedures

Step-by-step mounting instructions for indoor and outdoor units.

  1. Install wall bracket: Level and secure to studs with provided hardware
  2. Create wall penetration: 3" hole with proper sleeve installation
  3. Mount indoor unit: Hang on bracket, ensure level position
  4. Place outdoor unit: Concrete pad or vibration-absorbing pads
  5. Secure outdoor unit: Anchor bolts or vibration isolation mounts

CAUTION! Ensure wall can support unit weight (typically 15-30 lbs for indoor unit).

Refrigerant Piping

Proper refrigerant line installation and connection procedures.

  1. Route refrigerant lines: Through wall sleeve with proper insulation
  2. Flare connections: 45-degree angle, burr-free finish
  3. Connect lines: Indoor unit first, then outdoor unit
  4. Torque fittings: Manufacturer specifications (typically 18-22 ft-lbs)
  5. Insulate lines: Complete vapor barrier on suction line

WARNING! Never use compression fittings. Always purge with nitrogen during brazing.

Electrical Connections

Wiring and electrical connection guidelines.

  1. Install disconnect: Within sight of outdoor unit
  2. Connect power wiring: Follow color coding and torque specifications
  3. Run communication cable: Shielded cable between indoor and outdoor units
  4. Ground all units: Proper grounding per NEC requirements
  5. Verify voltage: 208/230V ±10%

CAUTION! Turn off power at disconnect before making electrical connections.

Vacuum and Leak Testing

System evacuation and leak detection procedures.

  1. Pressure test: Dry nitrogen to 300-500 PSI, hold for minimum 30 minutes
  2. Evacuate system: Deep vacuum to 500 microns or less
  3. Hold vacuum: System should hold 1000 microns or less for 15 minutes
  4. Release refrigerant: Open service valves per manufacturer instructions
  5. Leak check: Electronic leak detector or bubble solution

System Commissioning

Final setup and performance verification.

  1. Power up system: Turn on disconnect switch
  2. Test operation: Cooling and heating modes
  3. Check temperatures: Supply/return air, discharge line
  4. Verify drainage: Proper condensate flow
  5. Program remote: Set clock, timer functions
  6. Customer orientation: Explain basic operation and maintenance

Troubleshooting

Common installation issues and solutions.

SymptomPossible CauseCorrective Action
Unit not startingPower supply, wiringCheck disconnect, verify voltage, inspect connections
Poor coolingRefrigerant charge, airflowCheck superheat/subcooling, clean filters, verify fan operation
Water leakageDrain line, installation angleClear drain line, ensure proper unit leveling
Error codesSensor failure, communicationRefer to service manual, check sensor readings
Noisy operationVibration, loose partsSecure mounting, check for rattles, verify compressor mounts

Specifications