Fujitsu Halcyon Inverter Installation Manual
The Fujitsu Halcyon Inverter is a high-efficiency split-system air conditioning unit featuring advanced inverter technology, quiet operation, and energy-saving performance. This manual covers safety precautions, installation procedures, electrical connections, refrigerant piping, system commissioning, and maintenance guidelines for proper installation and operation.
Safety Precautions
Critical safety information for installers and users.
| Warning Type | Description |
| Electrical Safety | Disconnect all power before installation or servicing |
| Refrigerant Handling | Use proper tools and follow EPA guidelines for refrigerant |
| Lifting Safety | Use proper lifting equipment for heavy components |
| Fire Prevention | Keep unit away from flammable materials and sources |
| Ventilation | Ensure adequate airflow around indoor and outdoor units |
Unit Specifications
- Model Series: Halcyon Inverter Split Systems
- Cooling Capacity: 9,000 - 36,000 BTU/h
- Heating Capacity: 9,000 - 36,000 BTU/h
- Power Supply: 208/230V, 1-phase, 60Hz
- Refrigerant: R-410A
- Noise Level: As low as 19 dB(A) indoor
- Energy Efficiency: Up to 26 SEER
- Operating Range: Cooling: 14°F to 115°F; Heating: -13°F to 75°F
Installation Requirements
Pre-installation checklist and site preparation.
- Verify unit model matches installation requirements
- Check available space for indoor and outdoor units
- Ensure proper clearance around units (minimum 12 inches)
- Confirm electrical service meets unit requirements
- Prepare mounting surfaces and wall penetrations
WARNING! Installation must be performed by qualified HVAC technician only.
Mounting Procedures
Step-by-step mounting instructions for indoor and outdoor units.
- Indoor Unit: Mount on solid wall using template, ensure level installation
- Outdoor Unit: Place on stable pad or mounting brackets, allow vibration isolation
- Drill wall hole with 5° downward slope toward outdoor side
- Install wall sleeve and sealing grommet
- Secure all mounting hardware according to torque specifications
CAUTION! Ensure proper drainage slope for condensate removal.
Refrigerant Piping
Refrigerant line set installation and connection procedures.
- Measure and cut piping to required length
- Flare pipe ends using proper flaring tool
- Install insulation on both liquid and suction lines
- Connect piping to indoor and outdoor units
- Torque connections to manufacturer specifications
Tip: Keep piping runs as short and straight as possible for optimal performance.
Electrical Connections
Wiring and electrical connection guidelines.
| Connection | Specification |
| Power Supply | 208/230V ±10%, 1-phase, 60Hz |
| Circuit Breaker | Dedicated branch circuit required |
| Wire Size | Minimum 12 AWG for most models |
| Communication Wiring | Use shielded cable for control connections |
| Grounding | Proper equipment grounding mandatory |
Vacuum Drying
Evacuation and dehydration procedures.
- Connect vacuum pump to service ports
- Evacuate system to 500 microns or less
- Hold vacuum for 15 minutes to check for leaks
- If vacuum rises above 1000 microns, check for leaks
- Charge system with specified refrigerant amount
WARNING! Never release refrigerant to atmosphere - EPA violation.
System Commissioning
Final setup and performance verification.
- Power on system and check for error codes
- Verify proper airflow and temperature differential
- Check refrigerant pressures and superheat/subcooling
- Test all operating modes (cooling, heating, fan)
- Program remote control and test functions
Operation Settings
User controls and operational features.
- Temperature Control: 60°F to 86°F adjustable range
- Fan Speeds: Auto, Low, Medium, High, Quiet
- Operation Modes: Cool, Heat, Dry, Fan, Auto
- Timer Functions: 24-hour on/off programming
- Sleep Mode: Automatic temperature adjustment
- Filter Indicator: Reminds when to clean filters
Maintenance Guidelines
Routine maintenance procedures for optimal performance.
- Clean air filters every 2-4 weeks during operation
- Check and clean outdoor coil annually
- Inspect drain pan and condensate line quarterly
- Verify electrical connections annually
- Professional service recommended every 2 years
CAUTION! Always disconnect power before performing maintenance.
Troubleshooting
| Symptom | Possible Cause | Corrective Action |
| Unit not starting | Power supply, circuit breaker | Check power, reset breaker, verify voltage |
| Poor cooling/heating | Dirty filters, low refrigerant | Clean filters, check refrigerant charge |
| Water leakage | Clogged drain line | Clear condensate drain line |
| Unusual noise | Loose parts, fan issues | Tighten mounting, check fan assembly |
| Error codes displayed | Sensor failure, system fault | Refer to service manual for specific codes |