Fujitsu Halcyon Inverter Installation Manual

The Fujitsu Halcyon Inverter is a high-efficiency split-system air conditioning unit featuring advanced inverter technology, quiet operation, and energy-saving performance. This manual covers safety precautions, installation procedures, electrical connections, refrigerant piping, system commissioning, and maintenance guidelines for proper installation and operation.

1. Safety Precautions 2. Unit Specifications 3. Installation Requirements 4. Mounting Procedures 5. Refrigerant Piping 6. Electrical Connections 7. Vacuum Drying 8. System Commissioning 9. Operation Settings 10. Maintenance Guidelines 11. Troubleshooting

Safety Precautions

Critical safety information for installers and users.

Warning TypeDescription
Electrical SafetyDisconnect all power before installation or servicing
Refrigerant HandlingUse proper tools and follow EPA guidelines for refrigerant
Lifting SafetyUse proper lifting equipment for heavy components
Fire PreventionKeep unit away from flammable materials and sources
VentilationEnsure adequate airflow around indoor and outdoor units

Unit Specifications

Installation Requirements

Pre-installation checklist and site preparation.

  1. Verify unit model matches installation requirements
  2. Check available space for indoor and outdoor units
  3. Ensure proper clearance around units (minimum 12 inches)
  4. Confirm electrical service meets unit requirements
  5. Prepare mounting surfaces and wall penetrations

WARNING! Installation must be performed by qualified HVAC technician only.

Mounting Procedures

Step-by-step mounting instructions for indoor and outdoor units.

  1. Indoor Unit: Mount on solid wall using template, ensure level installation
  2. Outdoor Unit: Place on stable pad or mounting brackets, allow vibration isolation
  3. Drill wall hole with 5° downward slope toward outdoor side
  4. Install wall sleeve and sealing grommet
  5. Secure all mounting hardware according to torque specifications

CAUTION! Ensure proper drainage slope for condensate removal.

Refrigerant Piping

Refrigerant line set installation and connection procedures.

  1. Measure and cut piping to required length
  2. Flare pipe ends using proper flaring tool
  3. Install insulation on both liquid and suction lines
  4. Connect piping to indoor and outdoor units
  5. Torque connections to manufacturer specifications

Tip: Keep piping runs as short and straight as possible for optimal performance.

Electrical Connections

Wiring and electrical connection guidelines.

ConnectionSpecification
Power Supply208/230V ±10%, 1-phase, 60Hz
Circuit BreakerDedicated branch circuit required
Wire SizeMinimum 12 AWG for most models
Communication WiringUse shielded cable for control connections
GroundingProper equipment grounding mandatory

Vacuum Drying

Evacuation and dehydration procedures.

  1. Connect vacuum pump to service ports
  2. Evacuate system to 500 microns or less
  3. Hold vacuum for 15 minutes to check for leaks
  4. If vacuum rises above 1000 microns, check for leaks
  5. Charge system with specified refrigerant amount

WARNING! Never release refrigerant to atmosphere - EPA violation.

System Commissioning

Final setup and performance verification.

  1. Power on system and check for error codes
  2. Verify proper airflow and temperature differential
  3. Check refrigerant pressures and superheat/subcooling
  4. Test all operating modes (cooling, heating, fan)
  5. Program remote control and test functions

Operation Settings

User controls and operational features.

Maintenance Guidelines

Routine maintenance procedures for optimal performance.

  1. Clean air filters every 2-4 weeks during operation
  2. Check and clean outdoor coil annually
  3. Inspect drain pan and condensate line quarterly
  4. Verify electrical connections annually
  5. Professional service recommended every 2 years

CAUTION! Always disconnect power before performing maintenance.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower supply, circuit breakerCheck power, reset breaker, verify voltage
Poor cooling/heatingDirty filters, low refrigerantClean filters, check refrigerant charge
Water leakageClogged drain lineClear condensate drain line
Unusual noiseLoose parts, fan issuesTighten mounting, check fan assembly
Error codes displayedSensor failure, system faultRefer to service manual for specific codes

Service Contact: 1-888-888-3424; www.fujitsugeneral.com