The Fujitsu Ducted Air Conditioning System is a high-efficiency climate control solution designed for residential and commercial applications. This system features advanced inverter technology, multi-zone capability, intelligent airflow control, Wi-Fi connectivity, quiet operation, energy-saving modes, and comprehensive safety protections. Below are key sections for safety guidelines, system overview, installation procedures, electrical connections, commissioning, operation, maintenance, and troubleshooting.
Key components: Outdoor unit, Indoor unit, Ductwork system, Control panel, Remote controller, Drain system, Refrigerant piping.
| Component | Description |
|---|---|
| Outdoor Unit | Heat exchanger, compressor, fan motor, control board |
| Indoor Unit | Evaporator coil, blower motor, drain pan, air filter |
| Ductwork | Supply and return air ducts, dampers, grilles |
| Control System | Wall controller, remote, Wi-Fi module |
| Refrigerant Lines | Copper piping, insulation, flare connections |
| Electrical | Power supply, control wiring, circuit breakers |
| Drain System | Condensate drain line, trap, pump if required |
| Mounting Hardware | Brackets, vibration isolators, fasteners |
Critical safety measures must be followed during installation and maintenance.
WARNING! Failure to follow safety procedures may result in electric shock, fire, or personal injury. Only qualified technicians should perform installation.
Site preparation and equipment verification before installation.
CAUTION! Ensure installation site can support unit weight and vibration loads.
Power supply and control wiring installation guidelines.
Tip: Use conduit for all exposed wiring and label all connections.
Duct system design and installation procedures.
WARNING! Ensure ductwork is properly supported and sealed to prevent air leakage and noise.
Refrigerant line installation and charging procedures.
CAUTION! Only certified technicians should handle refrigerants. Follow all environmental regulations.
System startup, testing, and performance verification.
Tip: Record all test measurements for future reference and warranty validation.
Controller configuration and system programming.
Wall Controller: Mode selection, temperature setpoint, fan speed, timer functions.
Remote Control: All basic functions plus advanced features programming.
System Settings: Thermostat calibration, fan control, filter timer, system mode, zone control setup, Wi-Fi connectivity configuration, schedule programming, temperature limits, lock functions.
Regular maintenance procedures for optimal performance.
Monthly: Check and clean air filters. Quarterly: Inspect condensate drain system. Annually: Professional service including coil cleaning, electrical inspection, refrigerant check, and system performance test.
CAUTION! Always disconnect power before performing any maintenance. Use only manufacturer-approved parts.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power supply, circuit breaker | Check power at unit, reset breakers, verify control wiring. |
| Poor cooling/heating | Dirty filters, low refrigerant | Clean filters, check refrigerant charge, verify airflow. |
| Water leakage | Clogged drain, improper slope | Clear drain line, ensure proper drain slope. |
| Unusual noises | Loose parts, fan issues | Tighten all fasteners, check fan blades and motor. |
| Error codes displayed | Sensor failure, system fault | Refer to error code chart in service manual. |
Reset: Power cycle unit or use controller reset function.
Service: Contact authorized Fujitsu service center for professional assistance.