The Fujitsu ASU36CLX1 is a 36,000 BTU split-type air conditioning unit with inverter technology, R32 refrigerant, high energy efficiency rating, wireless remote control, auto-swing louvres, quiet operation, anti-mold filter, self-diagnosis function, and multiple operation modes (cooling, heating, dry, fan). Below are key sections for safety precautions, technical specifications, installation procedures, maintenance, troubleshooting, and repair guidelines.
Before servicing, ensure proper safety measures are followed to prevent injury and equipment damage.
| Hazard Type | Precaution |
|---|---|
| Electrical Shock | Disconnect power before servicing; use insulated tools |
| Refrigerant | Wear protective gloves and goggles when handling R32 |
| Heavy Parts | Use proper lifting techniques; two-person lift for outdoor unit |
| Sharp Edges | Wear cut-resistant gloves during disassembly |
| High Pressure | Release pressure before opening refrigerant lines |
| Rotating Parts | Ensure fan is stopped before working near blades |
Proper installation ensures optimal performance and longevity.
WARNING! Only certified technicians should install and service this equipment.
Follow electrical codes and manufacturer specifications for all connections.
| Connection | Specification |
|---|---|
| Power Supply | 208-230V, 60Hz, dedicated circuit with disconnect |
| Wire Size | Minimum 10 AWG copper wire |
| Circuit Breaker | 25A time-delay fuse or circuit breaker |
| Grounding | Proper equipment grounding required |
| Communication | Shielded cable between indoor and outdoor units |
Remote control functions and operational modes.
Remote Control: POWER, MODE (Auto/Cool/Dry/Fan/Heat), TEMP ▲▼, FAN SPEED, SWING, TIMER, SLEEP, RESET.
Operation Modes: Auto mode selects cooling or heating based on room temperature. Cooling mode maintains set temperature. Heating mode provides warmth. Dry mode reduces humidity. Fan mode circulates air without cooling/heating.
Regular maintenance ensures efficiency and prevents breakdowns.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power supply, remote batteries | Check circuit breaker; replace remote batteries |
| Poor cooling/heating | Dirty filters, low refrigerant | Clean filters; check refrigerant charge |
| Water leakage | Clogged drain, improper slope | Clear drain line; adjust slope |
| Unusual noise | Loose parts, fan obstruction | Tighten mounting; clear fan area |
| Error code displayed | System fault | Refer to error code section |
Authorized parts and replacement procedures.
| Code | Description | Action |
|---|---|---|
| E1 | Room temp sensor fault | Check thermistor resistance |
| E2 | Pipe temp sensor fault | Check pipe thermistor |
| E3 | Pressure sensor fault | Check pressure sensor circuit |
| E4 | Communication error | Check wiring between units |
| E5 | Inverter compressor fault | Check compressor and driver |
Complete electrical schematics for indoor and outdoor units.
Indoor Unit: Power input, fan motor, control board, thermistors, display PCB, remote sensor.
Outdoor Unit: Compressor, fan motor, 4-way valve, pressure sensors, inverter board, contactors.
Inter-unit: Communication wiring between indoor and outdoor control boards.
Proper procedures for R32 refrigerant management.
CAUTION! R32 is mildly flammable; no smoking or open flames during service.