Fujitsu ASU18RLF Manual

The Fujitsu ASU18RLF is a high-efficiency split-type air conditioning system with 18,000 BTU cooling capacity, featuring inverter technology for energy savings, quiet operation, multiple fan speeds, auto-swing louvers, 24-hour timer, remote control operation, air purification filter, and eco-friendly R32 refrigerant. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Components 7. Operating Modes 8. Maintenance Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Indoor unit, Outdoor unit, Remote Control, Power cable, Drain hose, Installation kit.

FeatureDescription
Cooling Capacity18,000 BTU/h
Heating Capacity19,000 BTU/h
Inverter TechnologyEnergy efficient operation with variable compressor speed
Noise LevelAs low as 19 dB indoor, 46 dB outdoor
RefrigerantR32 eco-friendly
Air FlowMulti-directional with auto-swing louvers
Filter SystemPlasma and dust air purification
Timer Function24-hour on/off timer
Remote ControlLCD display with full function control
Power Supply220-240V, 50/60Hz

Installation

Unpack and inspect contents. Choose appropriate location for indoor and outdoor units.

  1. Install outdoor unit: Place on stable, level surface with proper clearance for airflow.
  2. Install indoor unit: Mount on wall at least 2.2m from floor with proper tilt for drainage.
  3. Connect refrigerant pipes: Use flare connections with proper torque specification.
  4. Connect electrical wiring: Follow wiring diagram for proper connections.
  5. Connect drain hose: Ensure proper slope for water drainage.
  6. Vacuum and charge system: Evacuate air and moisture before charging with refrigerant.

WARNING! Installation must be performed by qualified technician. Ensure proper electrical grounding.

First-Time Setup

After installation, perform initial setup and testing.

  1. Power on system: Turn on circuit breaker and press power button on remote.
  2. Test operation: Run cooling mode for 15 minutes to verify proper function.
  3. Set temperature: Use remote to set desired temperature (16-30°C).
  4. Configure timer: Set daily operation schedule if needed.
  5. Adjust airflow: Set louver direction and fan speed preferences.

CAUTION! Allow system to stabilize for 10 minutes after power on before changing settings.

Specifications

Controls and Settings

Access functions via remote control or indoor unit buttons.

Remote Functions: POWER, MODE (Cool/Heat/Dry/Fan/Auto), TEMP ▲▼, FAN SPEED, TIMER, SWING, SLEEP, TURBO, I-FEEL, FILTER RESET.

Operation Modes: COOL for cooling, HEAT for heating, DRY for dehumidification, FAN for ventilation only, AUTO for automatic mode selection. Fan Speeds: AUTO, LOW, MEDIUM, HIGH, TURBO. Timer: 24-hour programmable on/off timer. Swing: Adjust vertical and horizontal air direction. Sleep: Automatic temperature adjustment for comfortable sleep.

Connecting Components

Proper connection between indoor and outdoor units is critical for operation.

  1. Refrigerant piping: Connect with flare nuts using proper torque (35-45 Nm).
  2. Electrical wiring: Connect power and communication cables according to wiring diagram.
  3. Drain hose: Connect with proper slope (minimum 1/100 gradient).
  4. Insulation: Apply insulation to all refrigerant pipes and connections.

Tip: Use nitrogen purge during brazing to prevent oxidation inside pipes.

Operating Modes

Multiple operation modes for different comfort needs.

  1. Cooling Mode: Set temperature between 16-30°C for cooling operation.
  2. Heating Mode: Set temperature between 16-30°C for heating operation.
  3. Dry Mode: Automatic dehumidification without significant cooling.
  4. Fan Mode: Air circulation only without cooling/heating.
  5. Auto Mode: System automatically selects cooling or heating based on room temperature.
  6. Turbo Mode: Maximum cooling/heating capacity for quick temperature adjustment.
  7. Sleep Mode: Gradually adjusts temperature and reduces fan noise for sleeping.
  8. I-Feel Mode: Uses remote control as temperature sensor for precise control.

WARNING! Do not operate heating mode below -15°C outdoor temperature.

Maintenance Features

Auto Clean: Dries indoor unit to prevent mold growth. Filter Indicator: Reminds when to clean air filter. Self-Diagnosis: Displays error codes for troubleshooting.

Care & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter every 2 weeks: Remove, wash with water, dry completely before reinstalling.
  2. Clean indoor unit surface: Use soft dry cloth only.
  3. Clean outdoor unit: Remove debris from heat exchanger fins.
  4. Check drain hose: Ensure proper drainage without blockage.

CAUTION! Always turn off power before cleaning. Do not use chemicals or abrasive cleaners.

Regulatory Information

CE Certified: Complies with European safety standards. RoHS Compliant: Free of hazardous substances. Energy Rating: Class A for energy efficiency. For technical support, visit www.fujitsu-general.com or contact local authorized service center. Manufactured under license from Fujitsu General Limited.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower supply/remoteCheck circuit breaker; replace remote batteries; ensure proper distance.
Poor cooling/heatingDirty filters/settingsClean air filter; check temperature setting; ensure doors/windows closed.
Water leakageClogged drainCheck drain hose for blockage; ensure proper installation slope.
Unusual noiseLoose parts/fanCheck for loose panels; ensure fan blades are clean and balanced.
Error code displayedSystem faultNote error code and contact authorized service center.

Reset: Turn off power for 10 minutes then restart.

Service: Contact authorized Fujitsu service center; www.fujitsu-general.com

Fujitsu ASU18RLF Manual © - All Rights Reserved 2025