Fujitsu ASU18CL Service Manual

The Fujitsu ASU18CL is a high-efficiency split-type air conditioning unit with advanced inverter technology, designed for residential and light commercial applications. This service manual provides comprehensive technical information for qualified service technicians, including safety precautions, technical specifications, installation procedures, maintenance guidelines, troubleshooting, and repair instructions.

1. Safety Precautions 2. Technical Specifications 3. Installation Procedures 4. Electrical Components 5. Refrigerant System 6. Control System 7. Maintenance Procedures 8. Troubleshooting Guide 9. Error Codes 10. Parts List 11. Wiring Diagrams

Safety Precautions

Before servicing, read all safety instructions carefully. Only qualified technicians should perform service operations.

Hazard TypePrecaution
Electrical ShockDisconnect power before servicing; use insulated tools
RefrigerantWear protective gloves and goggles when handling refrigerant
High PressureRelease pressure before opening refrigerant system
Moving PartsEnsure all moving parts are stopped before servicing
Hot SurfacesAllow components to cool before touching
Chemical ExposureUse proper ventilation when working with chemicals

Technical Specifications

Installation Procedures

Proper installation is critical for optimal performance and safety.

  1. Select installation location: Ensure adequate clearance and proper drainage
  2. Mount indoor unit: Use provided mounting plate and ensure level installation
  3. Install outdoor unit: Place on stable surface with proper vibration isolation
  4. Connect refrigerant piping: Use flare connections and proper torque
  5. Connect electrical wiring: Follow wiring diagram and local codes
  6. Vacuum and charge system: Evacuate to 500 microns, charge with R410A

WARNING! Incorrect installation may cause equipment damage, personal injury, or void warranty.

Electrical Components

Major electrical components and their functions.

ComponentFunctionSpecifications
CompressorDC Inverter typeVariable speed control
Indoor Fan MotorDC motor4-speed control
Outdoor Fan MotorDC motorVariable speed
PCB Main BoardSystem controlMicroprocessor based
Inverter PCBCompressor controlIPM module
ThermistorsTemperature sensingMultiple locations

Refrigerant System

Refrigerant circuit components and service procedures.

  1. Refrigerant Type: R410A (HFC)
  2. Charge Amount: Refer to unit nameplate
  3. Service Ports: High and low pressure ports
  4. Oil Type: POE oil
  5. Leak Testing: Use electronic leak detector or bubble solution
  6. Recovery: Use approved recovery equipment

CAUTION! R410A operates at higher pressures than R22. Use dedicated R410A tools and gauges.

Control System

Advanced control features and operation modes.

Maintenance Procedures

Routine maintenance for optimal performance and longevity.

  1. Air Filters: Clean every 2 weeks, replace every 6 months
  2. Heat Exchangers: Clean annually with soft brush
  3. Drain Pan: Clean and check for proper drainage
  4. Fan Blades: Clean and check balance
  5. Electrical Connections: Check for tightness and corrosion
  6. Refrigerant Charge: Verify proper charge and check for leaks

Troubleshooting Guide

Common problems and solutions.

SymptomPossible CauseCorrective Action
Unit not startingPower supply, fuse, thermostatCheck voltage, replace fuse, verify thermostat settings
Poor coolingDirty filters, low refrigerantClean filters, check refrigerant charge
Noisy operationLoose parts, fan issuesTighten components, check fan motor and blades
Water leakageClogged drain, improper slopeClear drain line, ensure proper unit leveling
Error code displaySystem faultRefer to error code section for specific diagnosis

Error Codes

Self-diagnosis error codes and their meanings.

CodeDescriptionAction Required
E0Protection of outdoor PCBCheck outdoor unit PCB and connections
E1Indoor/outdoor communication errorCheck wiring between indoor and outdoor units
E3High pressure protectionCheck refrigerant charge, condenser cleanliness
E4Low pressure protectionCheck for refrigerant leaks, proper charge
E5Compressor overloadCheck compressor, power supply, refrigerant
E6Communication errorCheck indoor PCB and wiring

Parts List

Major replacement parts and their part numbers.

Wiring Diagrams

Complete electrical wiring schematics for indoor and outdoor units.

Indoor Unit Wiring: Power supply, control wiring, fan motor connections, thermistor locations

Outdoor Unit Wiring: Compressor connections, fan motor, inverter PCB, protection devices

Inter-unit Wiring: Communication wiring between indoor and outdoor units

Note: Always disconnect power before working on electrical components. Refer to detailed wiring diagrams included with unit documentation.