The Fujitsu ASU12RLS is a high-efficiency split-type air conditioning system with 12,000 BTU cooling capacity, R410A refrigerant, inverter technology for energy savings, wireless remote control, auto-swing louvres, sleep mode, timer functions, and multiple operation modes. Designed for residential and light commercial use with easy installation and maintenance features. Below are key sections for safety precautions, installation procedures, electrical connections, refrigerant piping, testing, and maintenance.
Before installation, read all safety instructions carefully to prevent injury and equipment damage.
| Warning Type | Precaution |
|---|---|
| Electrical Safety | Disconnect all power sources before installation |
| Refrigerant Handling | Use proper tools and protective equipment |
| Lifting Safety | Use appropriate lifting equipment for heavy units |
| Installation Location | Ensure adequate ventilation and clearance |
| Tools Safety | Use insulated tools for electrical work |
Gather all necessary tools before beginning installation.
IMPORTANT! Use only tools in good condition to ensure proper installation.
Select appropriate location and install indoor unit securely.
WARNING! Ensure wall can support unit weight; use proper anchors.
Install outdoor unit on stable, level surface with adequate clearance.
CAUTION! Do not install where snow accumulation or direct water exposure may occur.
Connect refrigerant pipes between indoor and outdoor units.
WARNING! Never reuse refrigerant pipes; always use new properly sealed pipes.
Connect power supply and inter-unit wiring according to local codes.
| Connection | Specification |
|---|---|
| Power Supply | 115V, 15A dedicated circuit |
| Wire Size | 14 AWG minimum |
| Circuit Breaker | 15A time-delay fuse or breaker |
| Grounding | Proper earth ground required |
| Inter-unit Wiring | Follow color coding in manual |
CAUTION! All electrical work must be performed by qualified personnel.
Install proper drainage to prevent water damage.
IMPORTANT! Never elevate drain hose above indoor unit level.
Remove moisture and air from refrigerant system.
WARNING! Never release refrigerant to atmosphere; recover properly.
Test system operation and verify proper function.
NOTE: Allow system to run for at least 15 minutes for accurate performance assessment.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not cooling | Power issue/refrigerant | Check power supply; verify refrigerant charge |
| Water leakage | Clogged drain | Clean drain pipe; ensure proper slope |
| Unusual noise | Loose parts/fan | Tighten mounting; check fan blades |
| Poor airflow | Dirty filters | Clean or replace air filters |
| Remote not working | Batteries/sensor | Replace batteries; check IR sensor |
Maintenance Schedule: Clean filters monthly; professional service annually.
Service Contact: Fujitsu Technical Support: 1-800-831-8821