Fujitsu ASTG18KMCA Manual

The Fujitsu ASTG18KMCA is a high-efficiency split-type air conditioning system with 1.5HP cooling capacity, featuring inverter technology for energy savings, wireless remote control, auto-swing louvres, sleep mode, timer functions, dehumidification mode, and eco-friendly R32 refrigerant. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Remote Control Operation 7. Maintenance 8. Energy Saving Tips 9. Safety Precautions 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Indoor unit, Outdoor unit, Remote control, Installation accessories, User manual.

FeatureDescription
Cooling Capacity1.5HP (5.0kW)
Inverter TechnologyVariable speed compressor for energy efficiency
RefrigerantR32 eco-friendly
Remote ControlWireless with LCD display
Operating ModesCool, Heat, Fan, Dry, Auto
Air Flow DirectionAuto-swing louvres
Timer FunctionsOn/Off timer
Sleep ModeAutomatic temperature adjustment
Noise LevelLow noise operation
Energy RatingHigh efficiency 5-star rating

Installation

Professional installation required. Unpack and inspect all components.

  1. Select installation location: Indoor unit on interior wall, outdoor unit on stable surface.
  2. Mount indoor unit: Use mounting bracket provided, ensure level installation.
  3. Install outdoor unit: Place on concrete pad or mounting brackets.
  4. Connect refrigerant pipes: Use flare connections, ensure proper insulation.
  5. Electrical connections: Connect to dedicated circuit with proper grounding.
  6. Vacuum and charge system: Remove air and moisture, charge with R32 refrigerant.

WARNING! Installation must be performed by qualified technician. Incorrect installation may cause injury or damage.

First-Time Setup

After installation, perform initial setup and testing.

  1. Power on system: Turn on circuit breaker for indoor and outdoor units.
  2. Test remote control: Install batteries, point at indoor unit signal receiver.
  3. Select operating mode: Press MODE button to choose Cool, Heat, or Auto.
  4. Set temperature: Use temperature buttons to set desired comfort level.
  5. Test all functions: Verify cooling, heating, fan speeds, and timer operations.
  6. Adjust louvres: Set auto-swing or fixed position as preferred.

CAUTION! Allow system to stabilize for 10 minutes after initial startup.

Specifications

Controls and Settings

Control via remote control or indoor unit buttons. Main functions: POWER, MODE, TEMP, FAN, TIMER, SWING.

Operating Modes: COOL (blue snowflake), HEAT (red sun), DRY (water drop), FAN (fan symbol), AUTO (auto symbol).

Temperature Setting: 16°C to 30°C. Fan Speed: Auto, Low, Medium, High, Turbo. Timer: On/Off timer up to 24 hours. Swing: Auto vertical/horizontal louvre movement. Sleep Mode: Automatic temperature adjustment for comfortable sleep.

Remote Control Operation

Wireless remote with LCD display and full function control.

  1. Power: Turns unit on/off
  2. Mode: Cycles through operating modes
  3. Temperature: Adjusts set temperature
  4. Fan Speed: Selects air flow rate
  5. Swing: Controls louvre direction
  6. Timer: Sets on/off schedules
  7. Sleep: Activates sleep mode
  8. Turbo: Maximum cooling/heating
  9. Reset: Returns to default settings

Tip: Point remote directly at indoor unit signal receiver for reliable operation.

Maintenance

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filters: Remove and wash every 2 weeks during heavy use
  2. Clean indoor unit: Wipe with soft dry cloth
  3. Clean outdoor unit: Remove debris from fins and fan
  4. Check drainage: Ensure condensate drain is clear
  5. Professional service: Annual maintenance by qualified technician

WARNING! Always disconnect power before cleaning. Do not use water on electrical components.

Energy Saving Tips

Maximize efficiency and reduce energy consumption.

Safety Precautions

Important safety information for proper operation.

CAUTION! Do not operate with wet hands. Do not block air inlets or outlets. Do not insert objects into unit. Ensure proper electrical grounding. Keep children away from outdoor unit. In case of abnormal operation, turn off immediately and contact service.

Regulatory Information

Complies with relevant safety and environmental standards. R32 refrigerant has low global warming potential. For technical support, contact Fujitsu authorized service center or visit www.fujitsu-general.com. Warranty period: 5 years on compressor, 1 year on parts.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower supplyCheck circuit breaker; ensure remote batteries; verify power connection.
Poor cooling/heatingDirty filters/settingsClean air filters; check temperature setting; ensure doors/windows closed.
Water leakageBlocked drainCheck drain pipe for blockage; ensure proper installation slope.
Unusual noiseLoose parts/debrisCheck for loose panels; remove debris from outdoor unit fan.
Remote not workingBatteries/distanceReplace batteries; point remote at signal receiver; reduce distance.

Reset: Turn off at circuit breaker for 5 minutes, then restart.

Service: Contact Fujitsu authorized service center for professional assistance.

Fujitsu ASTG18KMCA Manual © - All Rights Reserved 2025