Fujitsu AOU48RLXFZ Installation Manual
The Fujitsu AOU48RLXFZ is a high-performance outdoor unit for split-type air conditioning systems with R32 refrigerant, designed for residential and commercial applications. This unit features inverter technology for energy efficiency, quiet operation, weather-resistant construction, and compatibility with various indoor units. Below are key sections covering safety precautions, technical specifications, installation procedures, electrical connections, commissioning, and maintenance guidelines.
Features at a Glance
Key components: Weather-resistant outdoor unit, inverter compressor, R32 refrigerant system, fan motor, heat exchanger, electrical terminal block, service valves, and drainage port.
| Feature | Description |
| Refrigerant | R32 eco-friendly refrigerant |
| Compressor | Inverter-driven rotary compressor |
| Operating Range | Cooling: 14°F to 115°F (-10°C to 46°C) |
| Power Supply | 208/230V, 60Hz, 1-phase |
| Sound Level | 54 dB(A) at nominal operation |
| Dimensions | 35.4" W × 27.6" H × 13.8" D (900 × 700 × 350 mm) |
| Weight | 121 lbs (55 kg) |
| Connections | Liquid and gas service valves, electrical terminal block |
| Protection | Weatherproof casing, anti-corrosion coating |
| Compatibility | Works with Fujitsu indoor units of matching capacity |
Safety Precautions
Read all instructions before installation. Use proper personal protective equipment.
- Disconnect power before servicing or installation.
- Use certified refrigerant handling equipment and follow local regulations.
- Ensure proper grounding of electrical components.
- Install unit on stable, level surface with adequate clearance.
- Verify refrigerant type (R32) before charging.
WARNING! R32 refrigerant is flammable; no smoking or open flames during installation. Ensure adequate ventilation.
Technical Specifications
- Model: AOU48RLXFZ
- Cooling Capacity: 48,000 BTU/h
- Heating Capacity: 51,000 BTU/h
- Power Input: Cooling: 4.8 kW, Heating: 5.2 kW
- Current Rating: 25 A max
- Refrigerant Charge: Factory pre-charged: 4.41 lbs (2.0 kg)
- Max Piping Length: 98 ft (30 m) between indoor and outdoor units
- Max Height Difference: 49 ft (15 m) outdoor above/below indoor unit
- Drain Connection: 3/8" PVC pipe
- Operating Ambient: -13°F to 115°F (-25°C to 46°C)
Installation Requirements
Select appropriate location and prepare necessary tools and materials.
- Location: Well-ventilated area, away from direct sunlight, minimum 12" clearance on all sides.
- Mounting: Concrete pad or sturdy wall bracket, level surface.
- Tools: Torque wrench, flaring tool, vacuum pump, manifold gauge, leak detector.
- Materials: Copper piping (ACR grade), insulation, electrical cable, conduit.
- Permits: Check local building codes and obtain necessary permits.
CAUTION! Do not install in confined spaces or areas with combustible gases.
Mounting Procedures
Proper mounting ensures stability and optimal performance.
- Position unit: Place on concrete pad or secure wall bracket with vibration isolators.
- Level unit: Use spirit level to ensure unit is perfectly horizontal.
- Secure fasteners: Use appropriate bolts and anchors for mounting surface.
- Clearance: Maintain minimum clearances - 12" sides, 48" front, 24" top.
- Drainage: Ensure proper slope for condensate drainage away from unit.
Tip: Use rubber vibration pads to reduce noise transmission.
Refrigerant Piping
Proper piping installation is critical for system performance.
- Pipe sizing: Use recommended diameter (liquid: 1/4", gas: 1/2") for maximum efficiency.
- Flaring: Create 45° flare connections using proper flaring tool.
- Bending: Use tube bender to avoid kinks; minimum bend radius 4x pipe diameter.
- Insulation: Apply closed-cell foam insulation to both pipes; seal joints with tape.
- Routing: Keep pipes straight and supported every 6-8 feet.
- Connections: Tighten flare nuts to specified torque (25-30 ft-lbs).
WARNING! Never use pipe thread sealant on flare connections.
Electrical Connections
Follow electrical codes and use proper wiring methods.
- Power disconnect: Install weatherproof disconnect within sight of unit.
- Wiring: Use copper conductors only; follow NEC guidelines for wire sizing.
- Grounding: Connect equipment grounding conductor to terminal block.
- Terminal connections: Match wire colors to terminal markings; torque to 15 in-lbs.
- Communication cable: Use shielded 2-conductor cable for indoor-outdoor communication.
- Conduit: Use liquid-tight conduit for outdoor wiring connections.
CAUTION! Turn off power at main breaker before making electrical connections.
Vacuum Drying & Leak Testing
Essential steps to ensure system integrity and performance.
- Pressure test: Use dry nitrogen to pressurize system to 150 psi; hold for 24 hours.
- Leak check: Apply bubble solution to all connections; use electronic leak detector.
- Evacuation: Connect vacuum pump to service ports; pull vacuum to 500 microns.
- Hold test: Isolate vacuum pump; verify vacuum holds below 1000 microns for 15 minutes.
- Charge refrigerant: Open service valves to release factory charge into system.
Tip: Use core removal tool for better vacuum performance.
Commissioning & Startup
Final checks and system activation.
- Visual inspection: Verify all connections, clearances, and mounting.
- Electrical check: Measure voltage at terminal block; verify proper grounding.
- Startup: Turn on power; set indoor unit to cooling mode.
- Operation check: Listen for abnormal noises; verify fan operation.
- Performance: Measure operating pressures and temperatures.
- Settings: Configure thermostat and remote control settings.
WARNING! Do not operate system if unusual sounds or smells are detected.
Maintenance & Service
Regular maintenance ensures optimal performance and longevity.
- Monthly: Clean air filters on indoor unit.
- Seasonal: Clean outdoor coil with soft brush and water.
- Annual: Professional inspection of refrigerant charge, electrical components.
- As needed: Clear debris from around outdoor unit.
- Winter: Install protective cover if unit will not be used.
CAUTION! Only qualified technicians should service refrigerant circuit.
Troubleshooting
| Symptom | Possible Cause | Corrective Action |
| Unit not starting | Power supply, disconnect switch | Check circuit breaker; verify disconnect is closed; check voltage. |
| Poor cooling/heating | Dirty filters, low refrigerant | Clean filters; check refrigerant charge; verify airflow. |
| Unusual noises | Loose parts, fan obstruction | Tighten mounting bolts; clear debris from fan; check for vibration. |
| Water leakage | Clogged drain, improper slope | Clear drain line; ensure proper drainage slope. |
| Error codes displayed | Sensor failure, communication error | Refer to service manual for specific error code resolution. |
Reset: Turn power off for 5 minutes, then restart.
Service: Contact authorized Fujitsu service center; 1-800-853-8573