Fujitsu AOU36RLXFZ Service Manual

The Fujitsu AOU36RLXFZ is a high-efficiency split-type air conditioning unit with R410A refrigerant, designed for residential and commercial applications. This service manual provides comprehensive technical information for qualified service technicians, including specifications, installation procedures, troubleshooting, maintenance guidelines, and safety precautions. Below are key sections for technical specifications, installation, operation, maintenance, and troubleshooting.

1. Technical Specifications 2. Safety Precautions 3. Installation Procedures 4. Electrical Connections 5. Operation and Control 6. Maintenance Procedures 7. Troubleshooting Guide 8. Error Code Definitions 9. Parts List and Diagrams 10. Refrigerant Handling

Technical Specifications

Key technical data for Fujitsu AOU36RLXFZ air conditioning unit.

SpecificationDescription
ModelAOU36RLXFZ
Cooling Capacity36,000 BTU/h
Heating Capacity38,000 BTU/h
Power Supply208-230V, 60Hz
RefrigerantR410A
Refrigerant Charge2.8 kg (factory charged)
Operating Current15.2A (cooling), 16.8A (heating)
Sound Level48 dB (indoor), 58 dB (outdoor)
Dimensions (Outdoor)34.6" x 28.7" x 13.8"
Net Weight121 lbs (outdoor unit)

Safety Precautions

Essential safety guidelines for installation and service.

  1. Disconnect all power sources before servicing.
  2. Wear appropriate PPE including gloves and safety glasses.
  3. Ensure proper ventilation when working with refrigerants.
  4. Verify electrical connections are secure and properly grounded.
  5. Use only authorized replacement parts.

WARNING! High voltage present - risk of electric shock. Only qualified technicians should perform service.

Installation Procedures

Step-by-step installation guidelines.

  1. Select installation location: Ensure adequate clearance (min 20" all sides outdoor unit).
  2. Mount outdoor unit: Use vibration-absorbing pads and secure mounting brackets.
  3. Install refrigerant piping: Connect flare joints with proper torque (35-45 ft-lbs).
  4. Connect drain hose: Ensure proper slope for water drainage.
  5. Evacuate and charge system: Vacuum to 500 microns, charge with R410A.

CAUTION! Do not bend refrigerant pipes sharply; minimum bend radius 4 inches.

Electrical Connections

Wiring and electrical specifications.

Tip: Verify voltage at installation site before connecting power.

Operation and Control

Operating modes and control functions.

Modes: Cooling, Heating, Dehumidification, Fan Only, Auto

Features: Temperature setting (61°F-88°F), Fan speed control (Auto/Low/Med/High), Timer functions, Sleep mode, Remote control operation, Self-diagnosis system.

Remote Control: POWER, MODE, TEMP ▲/▼, FAN SPEED, TIMER, SWING, RESET

Maintenance Procedures

Routine maintenance schedule and procedures.

  1. Clean air filters: Every 2 weeks during peak usage.
  2. Clean outdoor coil: Annually or as needed.
  3. Check refrigerant charge: Annually using subcooling method.
  4. Inspect electrical connections: Annually for tightness and corrosion.
  5. Clean drain pan and line: Every 6 months.

WARNING! Always disconnect power before performing maintenance.

Troubleshooting Guide

Common issues and solutions.

SymptomPossible CauseCorrective Action
Unit not startingPower supply, breaker, remoteCheck power, reset breaker, replace remote batteries
Poor cooling/heatingDirty filters, low refrigerantClean filters, check refrigerant charge
Water leakageClogged drain, improper slopeClear drain line, adjust slope
Unusual noiseLoose parts, fan obstructionTighten components, clear obstructions
Error code displaySystem faultRefer to error code definitions section

Error Code Definitions

Self-diagnosis error codes and meanings.

Error CodeDescriptionAction
E0Protection device activatedCheck for obstructions, reset
E1PCB communication errorCheck wiring connections
E3High pressure protectionCheck condenser, refrigerant charge
E4Low pressure protectionCheck for leaks, refrigerant level
E5Compressor overloadCheck voltage, compressor condition

Parts List and Diagrams

Major components and replacement parts.

Note: Use only genuine Fujitsu replacement parts.

Refrigerant Handling

R410A refrigerant procedures and precautions.

  1. Recovery: Use approved recovery machine and cylinders.
  2. Charging: Charge as liquid into high side only.
  3. Pressure: High pressure operation - use appropriate gauges.
  4. Leak testing: Use electronic leak detector or bubble solution.
  5. Disposal: Recover refrigerant, do not vent to atmosphere.

CAUTION! R410A operates at higher pressures than R22 - use dedicated equipment.