The Fujitsu AOU36RLXFZ is a high-efficiency split-type air conditioning unit with R410A refrigerant, designed for residential and commercial applications. This service manual provides comprehensive technical information for qualified service technicians, including specifications, installation procedures, troubleshooting, maintenance guidelines, and safety precautions. Below are key sections for technical specifications, installation, operation, maintenance, and troubleshooting.
Key technical data for Fujitsu AOU36RLXFZ air conditioning unit.
| Specification | Description |
|---|---|
| Model | AOU36RLXFZ |
| Cooling Capacity | 36,000 BTU/h |
| Heating Capacity | 38,000 BTU/h |
| Power Supply | 208-230V, 60Hz |
| Refrigerant | R410A |
| Refrigerant Charge | 2.8 kg (factory charged) |
| Operating Current | 15.2A (cooling), 16.8A (heating) |
| Sound Level | 48 dB (indoor), 58 dB (outdoor) |
| Dimensions (Outdoor) | 34.6" x 28.7" x 13.8" |
| Net Weight | 121 lbs (outdoor unit) |
Essential safety guidelines for installation and service.
WARNING! High voltage present - risk of electric shock. Only qualified technicians should perform service.
Step-by-step installation guidelines.
CAUTION! Do not bend refrigerant pipes sharply; minimum bend radius 4 inches.
Wiring and electrical specifications.
Tip: Verify voltage at installation site before connecting power.
Operating modes and control functions.
Modes: Cooling, Heating, Dehumidification, Fan Only, Auto
Features: Temperature setting (61°F-88°F), Fan speed control (Auto/Low/Med/High), Timer functions, Sleep mode, Remote control operation, Self-diagnosis system.
Remote Control: POWER, MODE, TEMP ▲/▼, FAN SPEED, TIMER, SWING, RESET
Routine maintenance schedule and procedures.
WARNING! Always disconnect power before performing maintenance.
Common issues and solutions.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power supply, breaker, remote | Check power, reset breaker, replace remote batteries |
| Poor cooling/heating | Dirty filters, low refrigerant | Clean filters, check refrigerant charge |
| Water leakage | Clogged drain, improper slope | Clear drain line, adjust slope |
| Unusual noise | Loose parts, fan obstruction | Tighten components, clear obstructions |
| Error code display | System fault | Refer to error code definitions section |
Self-diagnosis error codes and meanings.
| Error Code | Description | Action |
|---|---|---|
| E0 | Protection device activated | Check for obstructions, reset |
| E1 | PCB communication error | Check wiring connections |
| E3 | High pressure protection | Check condenser, refrigerant charge |
| E4 | Low pressure protection | Check for leaks, refrigerant level |
| E5 | Compressor overload | Check voltage, compressor condition |
Major components and replacement parts.
Note: Use only genuine Fujitsu replacement parts.
R410A refrigerant procedures and precautions.
CAUTION! R410A operates at higher pressures than R22 - use dedicated equipment.