The Fujinon SRD 92B is a professional surgical endoscope designed for medical procedures, featuring advanced optical technology, durable construction, and compatibility with various medical imaging systems. This manual provides comprehensive guidance on proper handling, maintenance, sterilization, and troubleshooting procedures to ensure optimal performance and patient safety.
The Fujinon SRD 92B surgical endoscope combines high-resolution imaging with ergonomic design for precision medical procedures. Key features include advanced fiber optics, durable construction, and compatibility with standard medical equipment.
| Feature | Description |
|---|---|
| Optical System | High-resolution rod lens system |
| Field of View | Wide-angle visualization |
| Working Length | Standard surgical procedure length |
| Diameter | Optimized for minimal invasiveness |
| Light Guide | Fiber optic illumination system |
| Compatibility | Standard light sources and cameras |
| Construction | Medical-grade stainless steel |
| Sterilization | Autoclave and chemical compatible |
The SRD 92B consists of several key components designed for optimal surgical performance and durability.
WARNING! Handle with care to avoid damage to optical components.
Proper preparation ensures optimal performance and patient safety.
CAUTION! Do not use if any damage is detected.
Follow these guidelines for safe and effective operation.
Important: Always follow standard surgical protocols.
Proper cleaning and sterilization are critical for patient safety.
WARNING! Follow manufacturer's sterilization guidelines exactly.
Regular maintenance ensures long-term reliability.
| Maintenance Task | Frequency | Procedure |
|---|---|---|
| Optical Inspection | Before each use | Check for scratches or damage |
| Connector Cleaning | Weekly | Clean with approved solutions |
| Full Inspection | Monthly | Comprehensive component check |
| Professional Service | Annually | Factory-authorized inspection |
Proper storage prevents damage and maintains performance.
| Problem | Possible Cause | Solution |
|---|---|---|
| Poor image quality | Dirty optics | Clean optical surfaces |
| No illumination | Light source issue | Check light source and connections |
| Dark spots in image | Fiber damage | Professional inspection required |
| Fogging | Temperature difference | Allow temperature equilibration |
| Connection issues | Worn connectors | Inspect and clean connectors |
Fujinon provides limited warranty coverage for the SRD 92B endoscope. Warranty terms and conditions are outlined in the product documentation. Contact authorized service centers for warranty claims.
For technical assistance, service, or additional information:
Emergency Service: Contact local Fujinon representative for urgent issues.