Fujiaire Air Conditioner Manual

The Fujiaire Air Conditioner is a high-efficiency cooling system with multiple operating modes, energy-saving features, remote control operation, programmable timer, air purification filters, dehumidification function, sleep mode, and adjustable fan speeds. Designed for residential and light commercial use with voltage compatibility for 110-120V AC. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Energy Saving Tips 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Indoor unit with LCD display, Remote Control, Air filters, Condenser unit, Drain hose, Power cord.

FeatureDescription
Cooling Capacity12,000 BTU/h for rooms up to 550 sq ft
Operating ModesCool, Heat, Fan, Dry, Auto
Fan SpeedsAuto, Low, Medium, High, Turbo
Timer Function24-hour programmable on/off timer
Sleep ModeAutomatic temperature adjustment for comfort
Air FilterWashable anti-bacterial filter
Remote ControlFull function remote with LCD display
Energy EfficiencyEnergy Star certified
Noise LevelAs low as 19 dB in quiet mode
Warranty5 years on compressor, 1 year parts

Installation

Unpack and inspect contents. Choose appropriate location for installation.

  1. Select installation location: Ensure proper clearance around unit (minimum 20 inches).
  2. Install mounting bracket: Secure to wall studs using provided hardware.
  3. Connect refrigerant lines: Follow manufacturer's instructions for proper connection.
  4. Electrical connection: Connect to dedicated 15-amp circuit.
  5. Drainage setup: Install drain hose with proper slope for water drainage.

WARNING! Installation should be performed by qualified technician. Improper installation may void warranty.

First-Time Setup

After installation, perform initial setup for optimal performance.

  1. Power on unit: Plug into dedicated electrical outlet.
  2. Remote control setup: Install batteries and pair with unit.
  3. Initial settings: Set temperature, mode, and fan speed preferences.
  4. Timer programming: Set daily operation schedule if desired.
  5. Test all functions: Verify cooling, heating, and fan operations.

CAUTION! Allow unit to stabilize for 10 minutes after initial startup.

Specifications

Controls and Settings

Access controls via remote or unit display panel. Front Panel: POWER, MODE, FAN SPEED, TEMPERATURE, TIMER.

Remote: POWER, MODE, TEMP UP/DOWN, FAN SPEED, TIMER, SLEEP, SWING, TURBO, DISPLAY.

Temperature: 60°F to 86°F adjustable in 1° increments. Fan Speed: Auto, Low, Medium, High, Turbo. Mode: Cool, Heat, Fan, Dry, Auto. Timer: 24-hour programmable. Sleep: Automatic temperature adjustment. Swing: Automatic louvers movement.

Operation Modes

Multiple operating modes for different comfort needs.

  1. Cool Mode: Standard air conditioning operation
  2. Heat Mode: Heating function for colder weather
  3. Fan Mode: Air circulation without cooling/heating
  4. Dry Mode: Dehumidification without significant cooling
  5. Auto Mode: Automatic selection based on room temperature
  6. Sleep Mode: Gradual temperature adjustment for nighttime comfort
  7. Turbo Mode: Maximum cooling/heating for rapid temperature change

Tip: Use Auto mode for energy efficiency and consistent comfort.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Air Filter Cleaning: Clean every 2 weeks during peak usage
  2. Outdoor Unit: Keep area clear of debris and vegetation
  3. Indoor Unit: Wipe with soft, dry cloth
  4. Drainage System: Check for clogs monthly
  5. Seasonal Storage: Cover outdoor unit when not in use

CAUTION! Always disconnect power before performing any maintenance.

Energy Saving Tips

Maximize efficiency and reduce energy consumption.

Regulatory Information

UL Listed: Complies with UL 484 standards. Energy Star Certified: Meets energy efficiency guidelines. EPA Refrigerant Compliance: Uses R410A refrigerant. Copyright © 2025 Fujiaire; all rights reserved. For technical support and warranty service, contact 1-800-FUJIAIRE or visit www.fujiaire.com.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not coolingDirty filters/thermostat settingClean filters; check temperature setting; ensure proper power supply.
Water leakageClogged drain lineClear drain line; ensure proper installation slope.
Unusual noisesLoose parts/fan obstructionCheck for loose components; clear fan area of obstructions.
Remote not workingBatteries/obstructionReplace batteries; ensure clear line of sight to unit.
Unit not turning onPower supply/timer settingCheck circuit breaker; verify timer is not active.
Poor cooling performanceDirty coils/high ambient tempClean indoor and outdoor coils; check for proper ventilation.

Reset: Turn unit off for 5 minutes, then restart.

Service: 1-800-FUJIAIRE; www.fujiaire.com