The Fuji PXR4 Temperature Controller is a high-precision digital temperature controller featuring PID control, multiple input types (thermocouple, RTD), relay/SSR outputs, dual display showing PV and SV, alarm functions, auto-tuning, communication capabilities, and robust construction for industrial applications. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Dual digital display, front panel keys, terminal block connections, communication port, mounting bracket.
| Feature | Description |
|---|---|
| Dual Display | Shows Process Value (PV) and Set Value (SV) simultaneously |
| PID Control | Proportional-Integral-Derivative control with auto-tuning |
| Input Types | Thermocouple (K, J, T, etc.), RTD (Pt100), voltage/current |
| Output Types | Relay, SSR drive, voltage/current output |
| Alarm Functions | Up to 4 alarm outputs with various modes |
| Communication | RS-485 communication capability |
| Auto-tuning | Automatic PID parameter optimization |
| Power Supply | 100-240V AC, 50/60Hz |
| Front Keys | SET, UP, DOWN, MODE for parameter adjustment |
| Protection | IP66 rated front panel for dust/water resistance |
Unpack and inspect contents. Mount in appropriate location.
WARNING! Ensure proper grounding and follow electrical safety standards. Disconnect power before wiring.
Power on controller; configure basic parameters.
CAUTION! Verify sensor type setting matches actual sensor to prevent measurement errors.
Access parameters via front panel keys. Normal display shows PV and SV.
Front Keys: SET (parameter access), UP/DOWN (value adjustment), MODE (mode selection).
Basic Settings: Input type, control output, alarm settings, PID parameters. Advanced Settings: Communication parameters, filter time constant, scaling, lock function. Operation: Press SET to enter setting mode, use UP/DOWN to adjust values, press SET to confirm.
Terminal block connections for power, input, output, and communication.
Tip: Use shielded cables for sensor inputs and keep separated from power lines.
Supports various control modes and functions.
WARNING! Do not touch terminals during operation. High voltage present.
Advanced features for specialized applications.
Communication Settings: Baud rate, address, protocol configuration. Input Scaling: Custom scaling for non-standard sensors. Output Limiting: Maximum output power limitation. Soft Start: Gradual power application to prevent thermal shock. Password Protection: Parameter lock to prevent unauthorized changes.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Disconnect power before any maintenance. Use only approved replacement parts.
CE compliant: Meets European EMC and low voltage directives. UL/cUL approved: Listed under UL 508 industrial control equipment. RoHS compliant: Meets restriction of hazardous substances requirements. Copyright © Fuji Electric Co., Ltd. For technical support, contact Fuji Electric or authorized distributor. Refer to local regulations for proper disposal.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Power supply | Check power connection and voltage; verify fuse. |
| Incorrect temperature reading | Sensor/wiring | Verify sensor type setting; check wiring and connections. |
| No control output | Output configuration | Check output type setting; verify load connection. |
| Unstable control | PID parameters | Perform auto-tuning; adjust PID parameters. |
| Communication failure | Cable/settings | Check cable connections; verify baud rate and address. |
| Alarm not functioning | Alarm settings | Verify alarm setpoints and output assignments. |
Reset: Initialize parameters if necessary (refer to manual for procedure).
Service: Contact Fuji Electric technical support or authorized service center.