The Fuji Mini VFD is a compact variable frequency drive designed for small motor applications, featuring digital control, multiple operating modes, built-in protection functions, keypad operation, analog/digital inputs, relay outputs, and adjustable frequency range. Rated for 230V AC single-phase input, 3-phase output. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Digital control panel, Terminal blocks for power and control, Cooling fan, LED status indicators, Potentiometer for speed adjustment.
| Feature | Description |
|---|---|
| Power terminals | For single-phase input and three-phase motor output |
| Control terminals | For start/stop control, speed reference, relay outputs |
| Digital keypad | For parameter setting and operation control |
| LED indicators | Power, run, fault status display |
| Cooling fan | For heat dissipation during operation |
| Potentiometer | Manual speed adjustment (0-10V) |
| RUN/STOP | Starts and stops motor operation |
| PROG/ESC | Enters programming mode or exits |
| UP/DOWN | Navigates parameters and adjusts values |
| RESET | Clears fault conditions |
Unpack and inspect contents. Mount in suitable enclosure.
WARNING! Disconnect power before installation. Ensure proper ventilation for cooling.
Apply power; initialize basic parameters.
CAUTION! Verify motor parameters before operation to prevent damage.
Access parameters via keypad or external controls. Front Panel: RUN/STOP, PROG/ESC, UP/DOWN, RESET.
Keypad Functions: RUN/STOP, Parameter navigation, Value adjustment, Fault reset.
Basic Parameters: Acceleration time (P01), Deceleration time (P02), Maximum frequency (P03), Base frequency (P04). Motor Parameters: Rated voltage (P05), Rated current (P06), Number of poles (P07). Control Parameters: Operating mode selection (P08), Stop method (P09).
Power: L1, L2 input; U, V, W motor output. Control: Digital inputs, analog inputs, relay outputs.
Tip: Use shielded cables for control wiring to reduce noise interference.
Supports V/F control and sensorless vector control.
WARNING! Do not change parameters while motor is running unless necessary.
Overcurrent Protection: Trips at 150% of rated current for 1 minute. Overload Protection: Electronic thermal protection based on motor current. Overvoltage/Undervoltage: Protects against power supply variations. Overtemperature: Monitors internal temperature and reduces output if overheating.
Disconnect power before maintenance. Clean exterior with dry cloth; check terminal tightness periodically.
CAUTION! Do not use compressed air for cleaning as it may drive dust inside the unit.
CE Compliant: Meets European EMC and low voltage directives. UL Recognized: Component recognition for North America. RoHS Compliant: Free of hazardous substances. Copyright © 2024 Fuji Electric; all rights reserved. For technical support, visit www.fujielectric.com or contact 1-800-555-1234.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display on keypad | Power supply | Check input voltage; verify power connections. |
| Motor not running | Control wiring/parameters | Check start signal; verify run command source. |
| Overcurrent fault | Motor/load issues | Check for motor short; reduce load; increase acceleration time. |
| Overvoltage fault | Regeneration/braking | Increase deceleration time; add braking resistor if needed. |
| Overtemperature | Cooling/ambient temperature | Ensure adequate ventilation; clean cooling fins. |
Reset: Press RESET button after fault condition is cleared.
Service: 1-800-555-1234; www.fujielectric.com