Fuji Mini VFD Manual

The Fuji Mini VFD is a compact variable frequency drive designed for small motor applications, featuring digital control, multiple operating modes, built-in protection functions, keypad operation, analog/digital inputs, relay outputs, and adjustable frequency range. Rated for 230V AC single-phase input, 3-phase output. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Operating Modes 8. Protection Features 9. Maintenance & Care 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, Terminal blocks for power and control, Cooling fan, LED status indicators, Potentiometer for speed adjustment.

FeatureDescription
Power terminalsFor single-phase input and three-phase motor output
Control terminalsFor start/stop control, speed reference, relay outputs
Digital keypadFor parameter setting and operation control
LED indicatorsPower, run, fault status display
Cooling fanFor heat dissipation during operation
PotentiometerManual speed adjustment (0-10V)
RUN/STOPStarts and stops motor operation
PROG/ESCEnters programming mode or exits
UP/DOWNNavigates parameters and adjusts values
RESETClears fault conditions

Installation

Unpack and inspect contents. Mount in suitable enclosure.

  1. Mounting: Secure to flat surface using provided mounting holes.
  2. Power wiring: Connect L1, L2 for single-phase input; U, V, W for motor output.
  3. Control wiring: Connect start/stop signals, speed reference inputs.
  4. Grounding: Ensure proper grounding for safety and noise reduction.

WARNING! Disconnect power before installation. Ensure proper ventilation for cooling.

First-Time Setup

Apply power; initialize basic parameters.

  1. Motor data setup: Enter motor rated voltage, current, and frequency.
  2. Operating mode: Select V/F control or sensorless vector control.
  3. Acceleration/deceleration: Set ramp times according to application.
  4. Frequency limits: Set minimum and maximum operating frequencies.

CAUTION! Verify motor parameters before operation to prevent damage.

Specifications

Controls and Settings

Access parameters via keypad or external controls. Front Panel: RUN/STOP, PROG/ESC, UP/DOWN, RESET.

Keypad Functions: RUN/STOP, Parameter navigation, Value adjustment, Fault reset.

Basic Parameters: Acceleration time (P01), Deceleration time (P02), Maximum frequency (P03), Base frequency (P04). Motor Parameters: Rated voltage (P05), Rated current (P06), Number of poles (P07). Control Parameters: Operating mode selection (P08), Stop method (P09).

Connecting Devices

Power: L1, L2 input; U, V, W motor output. Control: Digital inputs, analog inputs, relay outputs.

  1. Disconnect all power before wiring.
  2. Connect motor wires to U, V, W terminals.
  3. Wire control signals according to application requirements.
  4. Connect ground wire to chassis ground terminal.

Tip: Use shielded cables for control wiring to reduce noise interference.

Operating Modes

Supports V/F control and sensorless vector control.

  1. Keypad operation: Use RUN/STOP and speed potentiometer.
  2. External control: Use digital inputs for remote operation.
  3. Multi-speed operation: Program up to 7 preset speeds.
  4. PID control: For process control applications.
  5. Jog operation: For precise positioning.
  6. DC braking: For quick stopping.
  7. Auto restart: Automatic restart after power recovery.
  8. Frequency jump: Avoid mechanical resonance frequencies.

WARNING! Do not change parameters while motor is running unless necessary.

Protection Features

Overcurrent Protection: Trips at 150% of rated current for 1 minute. Overload Protection: Electronic thermal protection based on motor current. Overvoltage/Undervoltage: Protects against power supply variations. Overtemperature: Monitors internal temperature and reduces output if overheating.

Maintenance & Care

Disconnect power before maintenance. Clean exterior with dry cloth; check terminal tightness periodically.

CAUTION! Do not use compressed air for cleaning as it may drive dust inside the unit.

Regulatory Information

CE Compliant: Meets European EMC and low voltage directives. UL Recognized: Component recognition for North America. RoHS Compliant: Free of hazardous substances. Copyright © 2024 Fuji Electric; all rights reserved. For technical support, visit www.fujielectric.com or contact 1-800-555-1234.

Troubleshooting

SymptomPossible CauseCorrective Action
No display on keypadPower supplyCheck input voltage; verify power connections.
Motor not runningControl wiring/parametersCheck start signal; verify run command source.
Overcurrent faultMotor/load issuesCheck for motor short; reduce load; increase acceleration time.
Overvoltage faultRegeneration/brakingIncrease deceleration time; add braking resistor if needed.
OvertemperatureCooling/ambient temperatureEnsure adequate ventilation; clean cooling fins.

Reset: Press RESET button after fault condition is cleared.