Fuji Frenic 5000G11 Manual Download
The Fuji Frenic 5000G11 is a high-performance industrial inverter designed for precise motor control applications. This advanced frequency converter features robust construction, comprehensive protection functions, and flexible programming capabilities suitable for various industrial environments. Below are key sections covering specifications, installation, operation, programming, maintenance, and troubleshooting.
Product Overview
The Fuji Frenic 5000G11 series represents the latest generation of industrial inverters with enhanced performance and reliability features.
| Feature | Description |
| Control Method | V/F Control, Sensorless Vector Control |
| Frequency Range | 0.1 to 400 Hz |
| Input Voltage | 200-240V AC, 380-480V AC (3-phase) |
| Output Capacity | 0.4 to 630 kW |
| Display Unit | Digital operator with LCD |
| Communication | RS-485, Modbus RTU |
| Protection Rating | IP20 (standard) |
| Ambient Temperature | -10°C to +50°C |
| Storage Temperature | -20°C to +65°C |
Technical Specifications
- Model Series: Frenic 5000G11
- Input Power: 3-phase 200-240V/380-480V ±10%
- Output Power: 3-phase, 0 to rated input voltage
- Carrier Frequency: 0.5 to 15 kHz (adjustable)
- Control Characteristics: Digital operator/keypad operation
- Acceleration/Deceleration: 0.1 to 3600 seconds
- Braking: Regenerative braking/DC injection braking
- Protection Functions: Overcurrent, overvoltage, undervoltage, overload, overheating
- Standards Compliance: CE, UL, cUL
Installation Guidelines
Proper installation is crucial for optimal performance and safety.
- Mounting: Install in clean, dry location with adequate ventilation.
- Clearance: Maintain minimum 100mm clearance on all sides for cooling.
- Environment: Avoid areas with excessive dust, moisture, or corrosive gases.
- Grounding: Ensure proper grounding according to local electrical codes.
- Vibration: Mount on vibration-resistant surface if required.
WARNING! Installation must be performed by qualified personnel only. Disconnect all power before installation.
Wiring Connections
Follow proper wiring procedures to ensure safe operation.
- Power Wiring: Connect R/L1, S/L2, T/L3 to power supply; U/T1, V/T2, W/T3 to motor.
- Control Wiring: Use shielded cables for control signals; keep separate from power cables.
- Grounding: Connect grounding terminal to proper earth ground.
- Braking Resistor: Connect if dynamic braking required.
- Communication: Connect RS-485 terminals for network communication.
CAUTION! Ensure all connections are tight and properly insulated.
Basic Operation
Operating the Frenic 5000G11 through the digital operator.
- Power On: Apply power; display shows ready status.
- Run Command: Use RUN key or external signal to start motor.
- Frequency Setting: Adjust output frequency via potentiometer or digital setting.
- Monitoring: View operating parameters on LCD display.
- Stop: Use STOP key or external signal to stop motor.
Key Functions: RUN, STOP, RESET, UP/DOWN arrows, ENTER, ESC
Parameter Settings
Essential parameters for basic configuration.
| Parameter | Function | Setting Range |
| F01 | Frequency Reference 1 | 0.1 to 400 Hz |
| F02 | Operation Method Selection | 0-3 |
| F03 | Maximum Output Frequency | 50 to 400 Hz |
| F04 | Base Frequency | 0.1 to 400 Hz |
| F05 | Rated Voltage | 0 to 1000V |
| F06 | Acceleration Time 1 | 0.1 to 3600 sec |
| F07 | Deceleration Time 1 | 0.1 to 3600 sec |
| F08 | Electronic Thermal | 0.1 to 500.0A |
Protection Functions
Comprehensive protection ensures equipment safety.
- Overcurrent Protection (OC): Trips at 200% rated current
- Overvoltage Protection (OV): Activates when DC bus voltage exceeds limit
- Undervoltage Protection (UV): Protects against low input voltage
- Overload Protection (OL): Electronic thermal protection for motor
- Overheating Protection (OH): Monitors heatsink temperature
- Short Circuit Protection: Instantaneous trip for output short circuits
- Ground Fault Protection: Detects ground faults in motor circuit
Maintenance Procedures
Regular maintenance ensures long-term reliability.
- Visual Inspection: Check for dust accumulation, loose connections, corrosion.
- Cleaning: Use dry compressed air to remove dust from heatsinks.
- Terminal Check: Verify tightness of power and control terminals.
- Cooling System: Ensure fans operate properly; replace if noisy or not spinning.
- Capacitors: Check for bulging or leakage in DC bus capacitors.
WARNING! Always disconnect power before performing maintenance.
Troubleshooting Guide
| Symptom | Possible Cause | Corrective Action |
| No display | Power supply issue | Check input power; verify control voltage |
| Motor not running | Run command missing | Check run signal; verify parameter settings |
| Overcurrent fault | Motor overload/short | Check motor connections; reduce load |
| Overvoltage fault | Deceleration too fast | Increase deceleration time; add braking resistor |
| Overheating fault | Insufficient cooling | Clean heatsink; check fan operation |
| Communication error | Wiring/parameter issue | Check communication cables; verify settings |
Download Options
Access complete documentation for the Fuji Frenic 5000G11 series.
- Full User Manual (PDF, 2.5MB)
- Installation Guide (PDF, 1.2MB)
- Programming Manual (PDF, 3.1MB)
- Technical Specifications (PDF, 0.8MB)
- Wiring Diagrams (PDF, 1.5MB)