The Fuji Electric PXR4 is a high-performance digital temperature controller featuring advanced PID control, universal input compatibility, dual digital displays, relay/SSR outputs, communication capabilities, and user-friendly operation. Designed for precise temperature regulation in industrial applications with robust construction and comprehensive functionality. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Dual digital displays, front panel controls, universal input terminals, output relays, communication ports, and mounting hardware.
| Feature | Description |
|---|---|
| Dual displays | PV (process value) and SV (set value) simultaneous display |
| Universal input | Compatible with thermocouples, RTDs, and voltage/current inputs |
| PID control | Advanced PID algorithm with auto-tuning capability |
| Output types | Relay, SSR drive, voltage pulse, and current outputs |
| Communication | RS-485 Modbus RTU communication support |
| Alarm functions | Multiple alarm outputs with adjustable hysteresis |
| Power supply | 100-240V AC, 50/60Hz universal input |
| Front panel | IP66 rated for dust and water protection |
| Mounting | DIN rail or panel mounting options |
| Memory backup | Non-volatile memory for parameter storage |
Unpack and inspect contents. Ensure proper mounting location.
WARNING! Disconnect power before wiring. Ensure proper grounding for safety.
Apply power; configure basic parameters.
CAUTION! Verify sensor type before power on to prevent damage.
Front panel: PV/SV displays, SET key, UP/DOWN keys, MODE key.
Parameter access: Press MODE key to enter parameter setting mode.
Basic parameters: Input type (IN-T), control action (P, I, D values), alarm types (AL1, AL2), setpoint (SV). Advanced parameters: Communication address (Addr), baud rate (bAud), control period (CtL), input shift (InS), output limit (oUL).
Terminal assignments: Power (L, N), input (+, -), control output (OUT, COM), alarm outputs (AL1, AL2, COM), communication (S+, S-).
Tip: Use shielded cables for sensor inputs in noisy environments.
Supports automatic control, manual mode, and standby operation.
WARNING! Do not change modes during critical processes.
PID auto-tuning: Automatically calculates optimal P, I, D parameters. Communication: Modbus RTU protocol for remote monitoring/control. Program control: Multi-segment profile operation. Password protection: Parameter access restriction.
Disconnect power before maintenance. Clean with dry cloth only; no solvents.
CAUTION! Do not use compressed air for cleaning; may damage internal components.
CE compliant: Meets European EMC and low voltage directives. UL/cUL recognized: Component recognition for North America. RoHS compliant: Meets restriction of hazardous substances. Copyright © Fuji Electric Co., Ltd. For technical support, contact local Fuji Electric distributor or visit www.fujielectric.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Power supply | Check power connection and voltage; verify fuse. |
| Incorrect temperature | Sensor/wiring | Verify sensor type setting; check wiring and connections. |
| No control output | Settings/wiring | Check output configuration; verify load connections. |
| Unstable control | PID tuning | Perform auto-tuning; adjust PID parameters manually. |
| Communication failure | Wiring/settings | Verify cable connections; check address and baud rate. |
Reset: Initialize parameters if configuration errors occur.
Service: Contact authorized Fuji Electric service center for repairs.